852 research outputs found

    Dependence of implantation angle of the transverse, intrafascicular electrode (TIME) on selective activation of pig forelimb muscles

    Get PDF

    Оценка средней скорости на 10-и метровой глубине для разрезов с высокоскоростным верхним слоем при микрорайонировании

    Get PDF
    Описываются способы оценки средней скорости поперечной волны на 10-и метровой глубине для разрезов, верхняя часть которых представлена уплотненным насыпным грунтом или мерзлыми породами

    Mahi-mahi (Coryphaena hippurus) life development: morphological, physiological, behavioral and molecular phenotypes.

    Get PDF
    BackgroundMahi-mahi (Coryphaena hippurus) is a commercially and ecologically important fish species that is widely distributed in tropical and subtropical waters. Biological attributes and reproductive capacities of mahi-mahi make it a tractable model for experimental studies. In this study, life development of cultured mahi-mahi from the zygote stage to adult has been described.ResultsA comprehensive developmental table has been created reporting development as primarily detailed observations of morphology. Additionally, physiological, behavioral, and molecular landmarks have been described to significantly contribute in the understanding of mahi life development.ConclusionRemarkably, despite the vast difference in adult size, many developmental landmarks of mahi map quite closely onto the development and growth of Zebrafish and other warm-water, active Teleost fishes

    Actively controlled release of Dexamethasone from neural microelectrodes in a chronic in vivo study

    Get PDF
    Stable interconnection to neurons in vivo over long time-periods is critical for the success of future advanced neuroelectronic applications. The inevitable foreign body reaction towards implanted materials challenges the stability and an active intervention strategy would be desirable to treat inflammation locally. Here, we investigate whether controlled release of the anti-inflammatory drug Dexamethasone from flexible neural microelectrodes in the rat hippocampus has an impact on probe-tissue integration over 12 weeks of implantation. The drug was stored in a conducting polymer coating (PEDOT/Dex), selectively deposited on the electrode sites of neural probes, and released on weekly basis by applying a cyclic voltammetry signal in three electrode configuration in fully awake animals. Dex-functionalized probes provided stable recordings and impedance characteristics over the entire chronic study. Histological evaluation after 12 weeks of implantation revealed an overall low degree of inflammation around all flexible probes whereas electrodes exposed to active drug release protocols did have neurons closer to the electrode sites compared to controls. The combination of flexible probe technology with anti-inflammatory coatings accordingly offers a promising approach for enabling long-term stable neural interfaces

    Transverse intrafascicular multichannel electrode (TIME) system for treatment of phantom limb pain in amputees

    Get PDF
    International audienceAIM: Phantom limb pain (PLP) develops in the lost limb in 50-80% of amputees. Today, it is not completely understood why the pain occurs, and no effective treatments are available. The favorable effect of electrical stimulation on PLP has been demonstrated. Our aim is to develop a novel system for manipulation of sensations by application of multi-channel microstimulation to the nerve stump of an amputee and explore this method as a treatment for clinched fist PLP (see figure). RESULTS: 1) Electrode design. Non-corrugated TIME electrodes with different dimensions and 8-12 active sites have been manufactued and tested in vivo and in vitro testing in the rat and pig. Methods for corrugated prototypes were developed and the first prototypes were realized. 2) Electrode selectivity modeling. A peripheral nerve model is under development to evaluate the electrode's selective stimulation properties and to optimize electrode design. Simulated currents and neural activity generated were qualitatively assessed using experimental data obtained from rat nerves. 3) Implant modeling. To optimize the implantation procedure, a theoretical peripheral nervous tissue model and a 3D FEM was implemented. Both models closely reproduce the experimental peripheral nervous tissue behaviour and simulate the insertion forces transmitted to the electrode during implantation. 4) Multi-channel stimulators and connectors. A 12-pole prototype, bench-top stimulator has been implemented and successfully tested in animal experiments. A high-count, implantable connector between stimulator and electrode has been designed. 5) Biocompatibility. Electrode materials were evaluated and did not induce immune rejection and significant inflammatory reaction after in vivo implantation in the rat. Electrode implantation will require an understanding of the fascicular characteristics of the target nerve. Morphological characteristics of the rat, pig and human nerves are currently evaluated and compared. 6) Animal testing. First TIME electrodes test were carried out in the acute rat and acute pig. Results indicated selective stimulation of different fascicles with graded recruitment. 7) Clinical evaluation: To quantify the location of artificially evoked sensations and evaluate the strength of artificially evoked sensations a psychophysical testing platform is under development. Main inclusion criteria for patient recruitment have been identified and protocols have been defined. CONCLUSION: The feasibility of the corrugated version of the TIME electrode has yet to be explored. Further work designing, optimizing and testing the TIME electrode and all technological developments will be carried out including theoretical stimulations and animal experimental work before the optimal electrode for human implant will be chosen
    corecore